site stats

Synthes screws

WebSynthes screw sizes and drives, as well as extraction instruments for removing broken and damaged screws. The set contains instruments to remove all screws with the following drive recesses: – Hex: 1.5 mm, 2.5 mm, 3.5 mm and 4.0 mm … WebThe EXPEDIUM ® 5.5 System provides technological advancements to treat a range of spinal pathologies. The EXPEDIUM Spine System offers a comprehensive solution for …

Synthes 3.5 mm Universal Drill Guide - A-Z Ortho

WebSynthes Small Fragment Instrument and Implant Set, with Self-Tapping Screws. Synthes 3.5/2.5 mm Double Drill Sleeve. Synthes 3.5 mm DCP Drill Guide, Neutral & Load. Synthes Bending Templates, For 2.7 mm & 3.5 mm Plates. Synthes Extra Small Bone Forceps, 10 mm. Synthes Small Hohmann-Style Retractor, 6 mm. http://synthes.vo.llnwd.net/o16/LLNWMB8/US%20Mobile/Synthes%20North%20America/Product%20Support%20Materials/Technique%20Guides/DSUSTRM09161080%20Rev%20B.pdf larissa chou menikah https://xhotic.com

510(k) Premarket Notification

WebDetermine screw and thread length 03.226.030 Direct Measuring Device for HCS 4.5 03.227.030 Direct Measuring Device for HCS 6.5 Remove the drill sleeve. Slide the narrow … WebWelcome to the Product Hub. On the DePuy Synthes Product Hub, you can filter and browse through our entire collection of orthopaedic products. Filter by Specialty, Anatomy, and/or … WebUniversal Screw Removal Set For the removal of intact and damaged screws The Universal Screw Removal Set removes screws from 0.9 mm to 3.2 mm diameter. Overview • Blades … larissa carolina loja

Surgical Technique

Category:Part of the DePuy Synthes Cannulated Screw System 4.0 mm …

Tags:Synthes screws

Synthes screws

Synthes Dhs Technique Guide

WebCannulated screws can be used with or without a washer (or support screw for the cannulated screw 3.0). Cannulated Screw Guide Wire Diameter Length Tip Art. no. 3.0 … http://synthes.vo.llnwd.net/o16/LLNWMB8/US%20Mobile/Synthes%20North%20America/Product%20Support%20Materials/Technique%20Guides/DSUSTRM09161079%20Rev%20B.pdf

Synthes screws

Did you know?

Web2 DePuy Synthes Screw Targeting Clamp Reference Guide *Note: The Compression Sleeve for the 6.5 mm Headless Compression Screw (03.227.033) will not fit down the outer sleeve of the Screw Targeting Clamp, however, compression can be achieved using the Screw Targeting Clamp. Features Provides the ability to maintain compression while inserting WebApr 6, 2024 · Headless Compression Screws Market report provides detailed profile and data information analysis of leading company includes Synthes, Smith & Nephew, Arthrex, Stryker, Medartis, Acumed, Wright ...

Web4.5 mm Cannulated Screws Surgical Technique DePuy Synthes 9 4. Insert screw Instruments 292.72 1.6 mm Threaded Guide Wire 314.20 Cannulated Hexagonal … WebCall our expert staff today at (520) 495-0391 or (888) ZGRUM88. * We also offer repair services for orthopedic power tools, gastroenterology and general surgery scopes and other medical equipment at 30-40% off manufacturer’s prices Write us for more information! Write to us at [email protected]

Web6 DePuy Synthes 3.5 Cannulated Screws Surgical Technique. Surgical Technique 3. Measure for screw length Instrument 319.15 Cannulated Screw Measuring Device Slide the tapered … WebDePuy Synthes 6.5 mm Titanium Recon Screws w/T25 Stardrive (70mm, 75mm, 80mm, 85mm, 90mm, 95mm, 105mm); part of the Expert Lateral Femur Nail System and indicated to stabilize Subtrochanteric fractures, Ipsilateral neck/shaft fractures, Femoral shaft fractures, Impending pathologic fractures, and malunions/Non-unions.

WebThe DePuy Synthes 4.0mm Cannulated Screws are intended for the fixation of fractures, osteotomies, fusions and nonunions of small bones and small bone fragments in adults …

http://www.cambridgeorthopaedics.com/easytrauma/classification/commonfiles/Synthes%20screws.pdf larissa cynthia jacobWebCannulated Compression Headless Screw (CCHS) System and Cannulated Screw System Plus (CSS+) offer surgeons uncompromised precision through: • Innovative cutting edge … larissa cybenkoWebThe DePuy Synthes 2.4 mm Headless Compression Screws are intended for fixation of fractures, osteotomies, non-unions, and malunions of small bones and small bone … larissa cyonWebThe distal Schanz screw should be placed parallel to the axis of the knee joint, in the posterior half of the condyle, approximately 2 cm to 3 cm from the articular surface and … larissa costa missWeb2.4 mm Cannulated Screw A part of the DePuy Synthes Cannulated Screw System (CSS) Self-drilling, self-tapping flutes 2.4 mm thread diameter Core diameter: • steel: 1.7 mm • … larissa cojanWebApr 6, 2024 · Bone Fixation Cannulated Screws Market Hitting New Highs by 2030 DePuy Synthes, Stryker, Zimmer Biomet, Smith & Nephew Published: April 6, 2024 at 7:02 a.m. ET larissa djomeniWebDePuy Synthes. Oct 2024 - Present1 year 7 months. Raynham, Massachusetts, United States. -Integral team member for the Conduit … larissa da silva oliveira